11.07.2019
VITA Update Messenger Version 190410
Dear valued customers and partners in sales and service,
the new software update 190410 for the:
VITA vPad excellence from serial number 2820170050 to serial number 2820180274
VITA vPad excellence from serial number 2820180275
VITA vPad comfort from serial number 3020180051
and the accompanying furnaces:
VITA VACUMAT 6000 M
VITA VACUMAT 6000 MP
VITA ZYRCOMAT 6000 MS
is now immediately available.
Details on how to install it are provided in the following instructions:
the new software update 190410 for the:
VITA vPad excellence from serial number 2820170050 to serial number 2820180274
VITA vPad excellence from serial number 2820180275
VITA vPad comfort from serial number 3020180051
and the accompanying furnaces:
VITA VACUMAT 6000 M
VITA VACUMAT 6000 MP
VITA ZYRCOMAT 6000 MS
is now immediately available.
Details on how to install it are provided in the following instructions:
Serial number-specific software updates
VITA vPad excellence
from serial number 2820170050 to serial number 2820180274
Software update version 190410 VITA vPad excellence from serial number 2820170050 to serial number 2820180274
VITA vPad comfort
beginning with serial number 3020180051
Software update version 190410 VITA vPad comfort beginning with serial number 3020180051
VITA vPad excellence
from serial number 2820180275
Software update version 190410 VITA vPad excellence beginning with serial number 2820180275
Information on the content
of software updates
This software update refers to the systems specified above, and is provided in generation-specific versions, due to extensive hardware and software changes. At IDS 2015, several software features were introduced that could not be implemented on models of the previous generation of the above-mentioned series, due to specific hardware incompatibility.
If you are interested in upgrading to the new software and hardware features, you can do so at any time by purchasing the latest generation of equipment, such as the control unit. The new control units are easy to install with dental furnaces from the series mentioned above of the generation prior to IDS 2015.
Content of software update 190410 for VITA vPad excellence from serial number 2820180275
– Bugfixing
– Cosmetic changes
– Online synchronization of date and time with the connected furnaces and automatic changeover to summer or winter time
– Marking of changed parameters: changed firing parameters are marked red until they are saved
– Backup: offers the possibility to save the complete design (background color, all profiles, and other settings) on a USB stick and to transfer it to another VITA vPad excellence from serial number 2820180275
– VITA profile: Updating the firing programs
– Furnace differentiation in the vPad: Each furnace can be assigned its own background color for better differentiation, analogous to the profile backgrounds
– Silver probe calibration.
Two programs are provided for the silver probe:
Program 1: 955 °C
Program 2: 965 °C
– VITA ZYRCOMAT 6100 MS is supported
– PDFs are updated
– Wi-Fi key keyboard expanded
Online update functionality
New updates are automatically displayed in the VITA vPad excellence and can be directly downloaded to the system via WLAN.
Upload of the process data
Process data of the furnace and the system data can be transmitted to VITA via WLAN on request by the user (also from the VITA FURNACE app).
The following data are sent to VITA:
– Device data
– All customer data
– The last 100 error messages
– Process data of all connected furnaces.
VITA FURNACE App
– The software version 190410 is required in order to use the VITA FURNACE app.
– Compatible with Android devices
– The VITA FURNACE app can be downloaded from the Google Playstore free of charge. Link to the Google Play Store
Functions of the VITA FURNACE app
– The current firing cycle can be followed live via the app
– Device data can be viewed and sent directly to the VITA device service team via the app
– Notification at the end of the firing program
– Firing system can be put into standby
– User videos
Content of software update 190410 for VITA vPad excellence from serial number 2820170050 to serial number 2820180274
– Bugfixing
– Cosmetic changes
– The "Lab" profile can be exported and imported. It is possible to perform a complete vPad backup on a USB disk.
– PDFs updated
– VITA ZYRCOMAT 6100 MS is supported.
Content of software update 190410 for VITA vPad comfort from serial number 3020180051
– Bugfixing
– Cosmetic changes
– The "Lab" profile can be exported and imported. It is possible to perform a complete vPad backup on a USB disk– PDFs updated.
– VITA ZYRCOMAT 6100 MS is supported.
Content of software update 190410 for VITA VACUMAT 6000 M/MP
– Troubleshooting during pellet detection
– Troubleshooting during communication with the VITA MultiPump
If you are interested in upgrading to the new software and hardware features, you can do so at any time by purchasing the latest generation of equipment, such as the control unit. The new control units are easy to install with dental furnaces from the series mentioned above of the generation prior to IDS 2015.
Content of software update 190410 for VITA vPad excellence from serial number 2820180275
– Bugfixing
– Cosmetic changes
– Online synchronization of date and time with the connected furnaces and automatic changeover to summer or winter time
– Marking of changed parameters: changed firing parameters are marked red until they are saved
– Backup: offers the possibility to save the complete design (background color, all profiles, and other settings) on a USB stick and to transfer it to another VITA vPad excellence from serial number 2820180275
– VITA profile: Updating the firing programs
– Furnace differentiation in the vPad: Each furnace can be assigned its own background color for better differentiation, analogous to the profile backgrounds
– Silver probe calibration.
Two programs are provided for the silver probe:
Program 1: 955 °C
Program 2: 965 °C
– VITA ZYRCOMAT 6100 MS is supported
– PDFs are updated
– Wi-Fi key keyboard expanded
Online update functionality
New updates are automatically displayed in the VITA vPad excellence and can be directly downloaded to the system via WLAN.
Upload of the process data
Process data of the furnace and the system data can be transmitted to VITA via WLAN on request by the user (also from the VITA FURNACE app).
The following data are sent to VITA:
– Device data
– All customer data
– The last 100 error messages
– Process data of all connected furnaces.
VITA FURNACE App
– The software version 190410 is required in order to use the VITA FURNACE app.
– Compatible with Android devices
– The VITA FURNACE app can be downloaded from the Google Playstore free of charge. Link to the Google Play Store
Functions of the VITA FURNACE app
– The current firing cycle can be followed live via the app
– Device data can be viewed and sent directly to the VITA device service team via the app
– Notification at the end of the firing program
– Firing system can be put into standby
– User videos
Content of software update 190410 for VITA vPad excellence from serial number 2820170050 to serial number 2820180274
– Bugfixing
– Cosmetic changes
– The "Lab" profile can be exported and imported. It is possible to perform a complete vPad backup on a USB disk.
– PDFs updated
– VITA ZYRCOMAT 6100 MS is supported.
Content of software update 190410 for VITA vPad comfort from serial number 3020180051
– Bugfixing
– Cosmetic changes
– The "Lab" profile can be exported and imported. It is possible to perform a complete vPad backup on a USB disk– PDFs updated.
– VITA ZYRCOMAT 6100 MS is supported.
Content of software update 190410 for VITA VACUMAT 6000 M/MP
– Troubleshooting during pellet detection
– Troubleshooting during communication with the VITA MultiPump
IMPORTANT INFORMATION
In order to keep the updates clear, there is an applicable furnace update for every vPad update associated with the same software version number.
Contact
VITA recommends performing software updates in order to ensure smooth operation of your systems.
Should you have any questions or comments regarding the software updates, please call VITA Equipment servicing:
Telephone numbers: +49 7761 562, ext. 101, 105, 106 or 114
email: instruments-service@vita-zahnfabrik.com.
Should you have any questions or comments regarding the software updates, please call VITA Equipment servicing:
Telephone numbers: +49 7761 562, ext. 101, 105, 106 or 114
email: instruments-service@vita-zahnfabrik.com.